Sikalastic®-560
Sikalastic®-560 is a cold-applied, one-component waterborne liquid applied waterproofing membrane, highly elastic and UV resistant.
Suitable for use in hot and tropical climatic conditions.
- One-component - ready to use
- Seamless waterproofing membrane
- UV resistant and resistant to yellowing and weathering
- Highly elastic and crack-bridging
- Non-toxic and VOC compliant water-based coating
- Excellent adhesion on porous and non-porous substrates
- Water vapour permeable - allows the substrate to breathe
Usage
- For roof waterproofing solutions in both new construction and refurbishment projects
- For roofs with many details and complex geometry when accessibility is limited
- For cost efficient life cycle extension of failing roofs
- For reflective coating to enhance energy efficiency by reducing cooling costs
Advantages
- One-component - ready to use
- Seamless waterproofing membrane
- UV resistant and resistant to yellowing and weathering
- Highly elastic and crack-bridging
- Non-toxic and VOC compliant water-based coating
- Excellent adhesion on porous and non-porous substrates
- Water vapour permeable - allows the substrate to breathe
Packaging
20 kg Containers
Colour
White
Product Details
APPROVALS / CERTIFICATES
- Fulfils requirements according ETAG-005 Part 8
- Fulfils initial solar reflectance requirements according Energy Star (0.820)
- Conforms to the requirements of LEED EQ Credit 4.2: Low –Emitting Materials: Paints & Coatings: VOC < 100 gm/lt
- USGBC LEED rating: conforms to LEED SS Credit 7.2- Heat Island Effect-Roof, SRI ≥ 78
- Meets requirements of external fire performance ENV 1187 BRoof (T1) on non-combustible substrates
- European Technical Approval
- Din 4062; 1978
Composition
Polyurethane modified acrylic dispersion
Shelf life
12 months from date of production if stored properly in original
Storage conditions
The product must be stored properly in original, unopened and undamaged sealed packaging in dry conditions at temperatures >+5 °C and <+30 °C.
Density
1.35 kg/l approx. (+23 °C) | (EN ISO 2811-1) |
Solid content
65 % approx. by weight (+23 °C / 50 % r.h.)
48 % approx. by volume (+23 °C / 50 % r.h.)
System Structure
Roof coating* | Reinforced roof waterproofing | |
Build up | Sikalastic®-560 is applied in 2 coats | Sikalastic®-560 is applied in 2 coats and reinforced with Sikalastic® Fleece-120 or Sika® Reemat Premium and sealed with 1 or 2 additional coats of Sikalastic®-560 |
Substrates | Concrete, metals, wood, tiles | Concrete, metals, wood, tiles, asphalt, bitumen felt |
Total consumption | 0.9–1.4 kg/m2 approx. | 2.1–2.8 kg/m2 approx. |
Dry film thickness | 0.3–0.5 mm approx. | 1.0–1.3 mm approx. |
*For partial reinforcement Sikalastic® Fleece-120 is applied at areas with high movement, irregular substrate or to bridge cracks, joints and seams on the substrate as well as for details.
Roof coating | Sikalastic®-560 3 years | Sikalastic®-560 5 years |
Build up | Sikalastic®-560 is applied in 2 coats | Sikalastic®-560 is applied in 2 or 3 coats |
Substrates | Sound concrete, metals, wood, tiles | Sound concrete, metals, wood, tiles |
Primer | Please refer to the Substrate Pre-Treatment table below. | Please refer to the Substrate Pre-Treatment table below. |
Total consumption | ≥ 0.9 kg/m2 (≥ 0.6 l/m2) applied in 1 or more coats | ≥ 1.4 kg/m2 (≥ 1 l/m2) applied in 2 coats |
Dry film thickness | 0.3 mm approx. | 0.5 mm approx. |
Roof waterproofing | Sikalastic®-560 10 years | Sikalastic®-560 15 years |
Build up | Sikalastic®-560 is applied in 2 coats, reinforced with Sikalastic® Fleece-120 or Sika® Reemat Premium and sealed with 1 coat of Sikalastic®-560 | Sikalastic®-560 is applied in 2 coats, reinforced with Sikalastic® Fleece-120 or Sika® Reemat Premium and sealed with 2 coats of Sikalastic®-560 |
Substrates | Sound concrete, metals, wood, tiles, bituminous membranes | Sound concrete, metals, wood, tiles, bituminous membranes |
Primer | Please refer to the Substrate Pre-Treatment table below. | Please refer to the Substrate Pre-Treatment table below. |
Total consumption | ≥ 2.1 kg/m2 (≥1.5 l/m2) applied in 3 coats | ≥ 2.8kg/m2 (≥ 2 l/m2) applied in 4 coats |
Dry film thickness | 1.0 mm approx. | 1.3 mm approx. |
Note: Do not apply more than 0.75 kg/m2 Sikalastic®-560 per coat for layers without reinforcement.
Tensile Strength
Free film: ~ 1.5 N/mm2 | (DIN 53504) |
With Sikalastic® Fleece-120: ~ 12 N/mm2 | (DIN 53504) |
Solar Reflectance
Initial | 0.821) |
1)All values refer to the inital (properly cured, non-weathered) status of Sikalastic®-560 white.
Thermal Emittance
0.931) | ASTM E 408, C1371, others |
1)All values refer to the inital (properly cured, non-weathered) status of Sikalastic®-560 white.
Solar Reflectance Index
102* | (ASTM E 1980) |
*All values refer to the initial (properly cured, non-weathered) status of Sikalastic®-560 white.
Service Temperature
–5 °C to +80 °C (intermittent)
Application
Ambient Air Temperature
+8 °C min / +35 °C max
Relative Air Humidity
5 %min ./ 80 % . max
Substrate Temperature
+8 °C min / +35 °C max
Dew Point
Beware of condensation. Surface temperature during application must be at least +3 °C above dew point.
Substrate Moisture Content
< 4 % moisture content.
No rising moisture according to ASTM (Polyethylene-sheet). No water / moisture / condensation on the substrate.
Substrate Pre-Treatment
Cementitious substrates
- Cementitious or mineral based substrates must be prepared mechanically using abrasive blast cleaning or scarifying equipment to remove cement laitance and to achieve an open textured surface.
- Loose friable material and weak concrete must be completely removed and surface defects such as blowholes and voids must be fully exposed.
- Repairs to the substrate, filling of joints, blowholes/voids and surface levelling must be carried out using appropriate products from the Sikafloor®, SikaDur® and SikaGard® range of materials.
- High spots must be removed by e.g. grinding.
- Outgassing is a naturally occurring phenomenon of concrete that can produce pinholes in subsequently applied coatings. The concrete must be carefully assessed for moisture content, air entrapment, and surface finish prior to any coating work. Any requirement for priming must also be considered. Installing the membrane either when the concrete temperature is falling or stable can reduce outgassing. It is generally beneficial, therefore, to apply the embedment coat in the late afternoon or evening.
Note: For the Waiting Time / Overcoating you shall refer to the PDS of the appropriate cleaner. Other substrates have to be tested for their compatibility. If in doubt, apply a test area first.
Waiting Time / Overcoating
Before applying Sikalastic®-560 on primer Sikalastic®-560 diluted with 10% water:
Substrate Temperature | Relative humidity | Minimum | |
+10°C | 50% | ~ 4 hours | |
+20°C | 50% | ~ 2 hours | |
+30°C |
| ~ 1 hours |
Before applying Sikalastic®-560 on Sikalastic®-560 (without fleece) allow 1st coat to dry
Substrate Temperature | Relative humidity | Minimum | |
+10°C | 50% | ~ 8 hours | |
+20°C | 50% | ~ 6 hours | |
+30°C |
| ~ 4 hours |
Before applying Sikalastic®-560 topcoat on Sikalastic®-560 reinforced with fleece allow material to dry:
| Maximum After thorough cleaning 1) Sikalastic®-560 can be overworked with itself at any time |
Note: Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
Applied Product Ready for Use
Temperature | Relative humidity | Rain resistant | Touch dry | Full cure |
+2°C | 50% | 1 hour | 6-8 hours | 12-16 hours |
+10°C | 50% | 1 hour | 3 hours | 6-8 hours |
+20°C | 50% | 1 hour | 2 hours | 4-6 hours |
Note: Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
SUBSTRATE PREPARATION
Substrate | Primer | Consumption (kg/m2) |
Cementitious substrate | Sikalastic®-560 diluted with 10 % water. | 0.3 approx. |
Brick and stone | Sikalastic®-560 diluted with 10 % water. | 0.3 approx. |
Ceramic tiles (unglazed) | Sikalastic®-560 diluted with 10 % water. | 0.3 approx. |
Bituminous felt | Only required for high reflectivity applications (Sikalastic® Metal Primer)* Fully reinforced system only | 0.2 approx. |
Bituminous coatings | Only required for high reflectivity applications (Sikalastic® Metal Primer)* Fully reinforced system only | 0.2 approx. |
Metals | Sikalastic® Metal Primer | 0.2 approx. |
Wooden substrates | Timber based roof tecks require a complete layer of Sikalastic® Carrier. For exposed timber upstands use Sikalastic®-560 diluted with 10 % water. | 0.3 approx. |
Paints | Subject to ahesion and compatiblity test |
* Sikalastic® Metal Primer prevents migration of bituminous volatiles and improves long-term reflectivity.
Note: These figures are theoretical and do not include for any additional material required due to surface porosity, surface profile, variations in level and wastage.
For the Waiting Time / Overcoating, please refer to the PDS of the appropriate cleaner and primer. Other substrates must be tested for their compatibility. If in doubt, apply a test area first.
MIXING
Prior to application, stir Sikalastic®-560 thoroughly for 1 minute in order to achieve a homogeneous mixture.
Over mixing must be avoided to minimise air entrainment.
APPLICATION
Prior the application of Sikalastic®-560 the priming coat if used must have cured tack-free. For the Waiting Time / Overcoating please refer to the PDS of the appropriate primer. Damageable areas (door frame) have to be protected with an adhesive tape
Roof Coating: Sikalastic®-560 is applied in two or three coats. Prior to the application of a 2nd coat the indicated waiting time in the table above shall be allowed.
Roof Waterproofing: Sikalastic®-560 is applied in combination with Sikalastic® Fleece 120 or Sika® Reemat Premium.
- Apply first coat of appr. 0.75 kg/m2 (for non-absorbing substrates) – 1.00 kg/m2 (for absorbing substrates) of Sikalastic®-560 on a length of approx. 1m.
- Roll in the Sikalastic® Fleece-120 or Sika® Reemat Premium and ensure that there are no bubbles or creases. Overlapping of the fleece minimal 5 cm.
- Apply second coat of appr. 0.25 kg/m2 - 0.5kg/m2 coat right into the wet fleece to achieve the required film thickness. The entire application shall happen while Sikalastic®-560 is still liquid, wet in wet.
- Repeat step 1–3 until the roof area is waterproofed.
- After the two coats are dry, seal the roof area with one or more additional coats of Sikalastic®-560 (≥ 0.5 kg/m² per coat).
Please note, always begin with details prior starting with waterproofing the horizontal surface.
For detailed information regarding application method please refer to Method Statement No. 850 94 03.
Tools:
Jet washer: If dust, vegetation, moss / algae or other contaminants are present on the existing roof, a power washer is required to clean the substrate prior to the application of SikaRoof® Systems. Existing chippings should be removed by hand or scabbling prior to power washing.
Squeegee:
Useful when removing excess water from the roof after overnight rain
Drill and paddle:
Sikalastic® -560 should be mixed for one minute using a drill and paddle.
Solvent resistant short-piled lamb skin roller: Used in the application of Sikalastic®-560 to ensure a consistent thickness of the seamless SikaRoof® systems.
Thick hair brush:
For application of Sikalastic®-560 to all details and penetrations.
Stanley knife:
This tool is required when cutting Sikalastic® Vap, Sikalastic® Insulation and Sikalastic® Carrier. When the Sikalastic® Insulation is resting on an uneven substrate, the back of the board should be cut to enable maximum contact with Sikalastic® Coldstick.
Saw:
Used when cutting thick Sikalastic® Insulation boards.
Airless spray equipment: Used only for the roof coating systems. Two spray applied layers is the minimum requirement. The pump should have the following parameter:
- min. pressure: 220 bar
- min. output: 5.1 l/min
- min. nozzle: 0.83mm (0.033 inch)
For example: Wagner Heavycoat HC 940 E SSP Spraypack
CLEANING OF EQUIPMENT